Current Clamp

Current clamp is an electrophysiological recording technique that measures how a cell’s membrane potential changes when a defined electrical current is injected, making it central to studying neuronal excitability. In a current-clamp configuration, a recording electrode applies steady or time-varying current while the amplifier records voltage responses, including depolarization, hyperpolarization, and action-potential firing. In neuroscience, this method reveals intrinsic membrane properties, firing thresholds, and synaptic integration in individual neurons and neural circuits. Comparing responses under different conditions can show how ion channels, neurotransmitters, drugs, or disease-related changes influence neuronal signaling and network function.

Current Clamp - Related Videos

Research

JoVE Journal - Neuroscience

Isolation of Sensory Neurons of Aplysia californica for Patch Clamp Recordings of Glutamatergic Currents

0 Views •

Cited by 5 •

2013

We describe the dissection of the nervous system of the marine sea hare Aplysia after anesthesia, the isolation of neurons for short term-tissue culture, and recordings of single cell ion currents via the patch clamp technique.

Applying Noise Currents to Medial Vestibular Nucleus Neurons Using Whole-Cell Patch-Clamp Technique

0 Views •

2025

This video demonstrates a protocol involving the application of subthreshold noise currents to medial vestibular nucleus neurons using the whole-cell patch-clamp technique to study the impact of the noise currents on neuronal sensitivity to electrical stimuli.

Research

JoVE Journal - Medicine

Voltage-Dependent Potassium Current Recording on H9c2 Cardiomyocytes via the Whole-Cell Patch-Clamp Technique

0 Views •

Cited by 1 •

2022

The present protocol describes an efficient method for the real-time and dynamic acquisition of voltage-gated potassium (Kv) channel currents in H9c2 cardiomyocytes using the whole-cell patch-clamp technique.

Recording of Inward Rectifying K+ Currents in Freshly Isolated Basilar Artery Smooth Muscle Cells by Patch Clamp Technique

0 Views •

2025

This protocol describes a rapid and efficient method for isolating smooth muscle cells from the rat basilar artery and recording inward rectifying potassium channel currents in these cells using the whole-cell patch clamp technique. It offers a novel approach for researchers studying the basilar artery and ion channels.

Amphotericin-B Mediated Perforated Patch-Clamp Analysis: An Electrophysiological Technique to Study Ionic Currents in Urinary Bladder Cells

0 Views •

2023

This video demonstrates the characterization of cationic currents from transient receptor potential melastatin type 4 (TRPM4) ion channels in detrusor smooth muscle cells using amphotericin-B mediated perforated patch-clamp technique. The technique helps evaluate the biophysical and pharmacological properties of ion channels.