Distal radius fractures are common injuries resulting from both low- and high-energy trauma1. For appropriately selected fractures, closed reduction followed by external immobilization remains an established nonoperative treatment option1. The goals of treatment are to restore acceptable alignment, maintain reduction during healing, preserve neurovascular function, and minimize complications related to immobilization. Common post-reduction immobilization methods include plaster casts, sugar-tong splints, volar-dorsal splints, and short-arm constructs; the choice depends on fracture stability, soft-tissue swelling, patient characteristics, local clinical practice, and available resources2,3. Fracture instability and the risk of secondary displacement should also be considered when selecting patients for continued conservative treatment4. Four-piece Chinese external splinting systems have also been described following successful manipulative reduction5.
Closed reduction of distal radius fractures is highly dependent on the direction and magnitude of applied forces, the sequence of correction, and maintenance of the achieved position during immobilization. Manual traction allows the operator to adjust force based on tactile feedback, whereas other approaches, such as finger-trap traction, provide sustained axial traction. Likewise, post-reduction immobilization can be achieved using several different constructs, and no single method is appropriate for every fracture pattern. These variations highlight the need for a clearly described and reproducible procedural sequence that defines patient selection, reduction maneuvers, splint application, and post-procedure assessment.
The present article describes a patient-specific four-splint immobilization technique used in the authors’ clinical practice. The construct uses separate volar, dorsal, radial, and ulnar splints that can be individually positioned and adjusted after reduction. This technique is presented as an alternative procedural method rather than as evidence of superiority over established plaster or splint constructs. The method is intended for appropriately selected dorsally displaced distal radius fractures in which closed reduction is clinically appropriate and acceptable alignment can be achieved and maintained.
The aim of this article is to provide a detailed, step-by-step visual protocol for manual reduction and four-splint immobilization of selected dorsally displaced distal radius fractures, with emphasis on the direction and sequence of reduction forces, maintenance of reduction during splint application, and serial neurovascular assessment.